Thermal Inspection & Electrical Testing
We use non-contact infrared thermography and hands-on electrical testing to find problems before they become failures — performed live under load, with no shutdown required, and delivered with clear, actionable reports.
Infrared (IR) Scanning
See what the eye can't — before it becomes a crisis.
Infrared thermography is the most effective way to detect electrical faults without taking equipment offline. Our calibrated thermal cameras capture heat signatures across panels, switchgear, transformers, motors, bus ducts, and connections — revealing hot spots that indicate loose connections, overloaded circuits, failing components, or imbalanced loads. All inspections are performed with equipment energized and under load, eliminating the arc flash exposure that comes with opening energized panels.
How It Works
Equipment Survey
We walk your facility and identify all electrical equipment to be scanned, confirming it is energized and under sufficient load (minimum 40% recommended) for accurate thermal readings.
Thermal Imaging
Using calibrated infrared cameras, we scan each piece of equipment and capture thermal images of any anomalies, recording temperature differentials, emissivity settings, and ambient conditions.
Analysis & Severity Rating
Each finding is analyzed and assigned a severity rating based on temperature rise above ambient — helping you prioritize repairs from immediate action required to monitor-only, in line with NFPA 70B guidelines.
Report Delivery
You receive a detailed report with side-by-side thermal and visual image pairs, temperature data, severity ratings, and recommended corrective actions for each finding — formatted for your insurer and maintenance records.
What You Receive
Electrical Testing
Verify system integrity before it fails under load.
Beyond thermal imaging, we perform hands-on electrical testing to assess the condition of your electrical infrastructure. Insulation resistance (megohmmeter) testing, power quality analysis, and load testing give you a complete picture of system health — identifying degradation that thermal cameras alone cannot detect, such as insulation breakdown in cables, motors, and transformers before it causes a fault.
How It Works
Scope & Safety Review
We review your single-line diagrams and equipment list, confirm safe isolation procedures, and establish the test plan with your facility team before any testing begins.
Insulation Resistance Testing
Megohmmeter testing on cables, motors, and transformers identifies insulation breakdown before it causes a fault — catching problems that are invisible to thermal cameras and preventing unexpected failures.
Power Quality & Load Analysis
We measure voltage, current, harmonics, and power factor to identify power quality issues that stress equipment, reduce efficiency, accelerate insulation aging, and shorten service life.
Test Report Delivery
Results are compiled into a structured report with pass/fail criteria, measured values, trend comparisons where available, and prioritized recommendations for corrective action.
What You Receive
Inspection Reports
Documentation your insurer, facility manager, and maintenance team can act on.
A thermal inspection is only as valuable as the report it produces. Our inspection reports are built to meet the documentation standards required by insurance carriers and to support NFPA 70B condition-based maintenance programs. Every report includes thermal and visual image pairs, temperature data, severity classifications, and clear corrective recommendations — giving your team a complete record of your facility's electrical health.
How It Works
Data Compilation
All thermal images, temperature readings, equipment identifiers, and field notes are compiled and organized by location and severity immediately after the inspection.
Image Annotation
Each thermal finding is paired with a visual photo and annotated with temperature markers, measurement points, and equipment identification for clear reference.
Severity Classification
Findings are classified by severity — from immediate action required to routine maintenance — using temperature differential criteria aligned with NFPA 70B and industry best practices.
Report Delivery
The completed report is delivered digitally, typically within 48 hours of the inspection, in a format ready for your insurer, facility management system, or maintenance program records.
What You Receive
Ready to Schedule an Inspection?
Don't wait for a failure to find out what's wrong. Our team travels nationwide to assess your facility and deliver a comprehensive thermal inspection report.